Sains Malaysiana 55(10)(2026): 1618-1625

http://doi.org/10.17576/jsm-2026-5510-02

 

Comparative Study of Chloroform and Dichloromethane Synthesized PMMA-Bismuth Nanocomposites for Enhanced X-Ray Attenuation

(Kajian Perbandingan Nanokomposit PMMA-Bismut yang Disintesis Kloroform dan Diklorometana untuk Atenuasi Sinar-X Dipertingkat)

 

WAN NORDIANA RAHMAN1,6,*, NURUL FAZLIN SYUHADA FAZLY1, RAIZULNASUHA AB RASHID2, AML AIEDS ALMUTERY1,3,6, KHAIRUNISAK ABDUL RAZAK4, ZURATUL AIN ABDUL HAMID4, MOHD KHALID MATORI5 & RATNA SUFFHIYANNI OMAR1,6

 

1Department of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia

2Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia

3Physics Department, Faculty of Science and Humanities in Ad-Dawadmi, Shaqra Iniversity, Shaqra 11911, Saudi Arabia

4School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Penang, Malaysia

5Malaysian Nuclear Agency, 43000 Kajang, Selangor, Malaysia

6Nuclear Technology Research Centre, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia

 

Received: 1 March 2026/Accepted: 10 September 2026

 

*Corresponding author; email: wnordiana@ukm.edu.my

 

Abstract

Radiation shielding is a critical component of safety protocols for protection against ionizing radiation. This study investigates the potential of Polymethyl Methacrylate (PMMA) doped with bismuth nanoparticles as a non-toxic, lead-free alternative for radiation shielding in medical diagnostics. PMMA-bismuth nanocomposites were synthesized and evaluated for their attenuation efficacy at diagnostic X-ray energies of 80 and 100 kVp. The influence of synthesis parameters specifically solvent type (chloroform and dichloromethane), solvent mass (2.5 g and 3.0 g), and bismuth nanoparticles (BiNP) loading (1%-5% wt) on shielding performance was systematically examined. Key shielding parameters, including the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), and tenth-value layer (TVL) were determined. Results indicate that LAC and MAC values for all samples increased proportionally with bismuth loading, while HVL and TVL values conversely decreased. The optimal shielding performance was observed in samples prepared using 2.5 g of chloroform with 5% BiNP loading at 80 kVp with the peak attenuation reached approximately 4.85 in comparison to 3.88 at 100 kVp for the same samples. These findings demonstrate that PMMA-bismuth nanocomposites are effective for diagnostic X-ray shielding and that synthesis parameters significantly influence their final attenuation properties.

Keywords: Bismuth nanoparticles; poly(methyl methacrylate); radiation shielding

 

Abstrak

Perisai sinaran merupakan komponen penting dalam protokol keselamatan bagi melindungi daripada sinaran pengion. Penyelidikan ini mengkaji potensiPolimetil Metakrilat (PMMA) yang didop dengan nanozarah bismut sebagai alternatif tidak toksik dan bebas plumbum untuk aplikasi perisai sinaran dalam diagnostik perubatan. Nanokomposit PMMA-bismut telah disintesis dan dinilai dari segi keberkesanan pelemahan sinaran pada tenaga sinar-X diagnostik iaitu 80 dan 100 kVp. Pengaruh parameter sintesis khususnya jenis pelarut (kloroform dan diklorometana), jisim pelarut (2.5 g dan 3.0 g) serta kandungan nanozarah bismut (BiNP) (1%-5% berat) terhadap prestasi perisai sinaran telah dikaji secara sistematik. Parameter utama perisai sinaran termasuk pekali pelemahan linear (LAC), pekali pelemahan jisim (MAC), lapisan separuh nilai (HVL) dan lapisan sepersepuluh nilai (TVL) telah ditentukan. Keputusan menunjukkan bahawa nilai LAC dan MAC bagi semua sampel meningkat secara berkadar dengan peningkatan kandungan bismut, manakala nilai HVL dan TVL menurun secara songsang. Prestasi perisai sinaran optimum diperoleh bagi sampel yang disediakan menggunakan 2.5 g kloroform bersama pemuatan BiNP 5% pada tenaga sinar-X 80 kVp dengan puncak pelemahan mencecah 4.85 berbanding 3.88 pada tenaga sinar-X 100 kVp untuk sampel yang sama. Keputusan ini menunjukkan bahawa nanokomposit PMMA-bismut berkesan untuk perisai sinar-X diagnostik dan parameter sintesis memainkan peranan penting dalam menentukan sifat pelemahan akhir bahan tersebut.

Kata kunci: Nanozarah bismut; perisai sinaran; poli(metil metakrilat)

 

REFERENCES

AbuAlRoos, N.J., Baharul Amin, N.A. & Zainon, R. 2019. Conventional and new lead-free radiation shielding materials for radiation protection in nuclear medicine: A review. Radiation Physics and Chemistry 165: 108439.

Adlienė, D., Gilys, L. & Griškonis, E. 2020. Development and characterization of new tungsten and tantalum containing composites for radiation shielding in medicine. Nuclear Instruments & Methods in Physics Research Section B-beam Interactions with Materials and Atoms 467: 21-26.

Alabsy, M.T., Abbas, M.I., El-Khatib, A.Y. & El-Khatib, A.M. 2024. Attenuation properties of poly methyl methacrylate reinforced with micro/nano ZrO2 as gamma-ray shields. Scientific Reports 14(1): 1279.

Almuqrin, A.H., Sayyed, M.I., Elsafi, M. & Khandaker, M.U. 2022. Comparison of radiation shielding ability of Bi2O3 micro and nanoparticles for radiation shields. Radiation Physics and Chemistry 200: 110170.

Almutery, A., Rahman, W.N., Mohamed, F., Hua, C.C., Razak, K.A., Rashid, R.A., Rilwan, U., Sayyed, M.I. & Maghrbi, Y. 2025a. Enhancing the gamma radiation shielding performance: The impact of Bi2O3 and MgO nanoparticles on PMMA. Radiation Physics and Chemistry 237: 113070.

Almutery, A.A., Rahman, W.N., Mohamed, F., Hua, C.C. & Ab Rashid, R. 2025b. SiO2-modified lead-free poly (methyl methacrylate) (PMMA) transparent nanocomposites: Structural, optical, and radiation shielding enhancements. The European Physical Journal Plus 140: 1258.

Almutery, A.A., Mohamed, F., Hua, C.C., Rahman W.N. & Al'-Kamali, M.F.S.H. 2026. Fabrication and optimization of the morphological, structural, and optical features of PMMA/MgO as promising nanocomposites for radiation shielding application: An experimental approach. Applied Radiation and Isotopes 231: 112525.

Alsaab, A.H. & Zeghib, S. 2023a. Study of prepared lead-free polymer nanocomposites for X- and gamma-ray shielding in healthcare applications. Polymers 15(9): 2142.

Alsaab, A.H. & Zeghib, S. 2023b. Analysis of X-ray and gamma ray shielding performance of prepared polymer micro-composites. Journal of Radiation Research and Applied Sciences 16(4): 100708.

Alshahri, S., Alsuhybani, M., Alosime, E., Almurayshid, M., Alrwais, A. & Alotaibi, S. 2021. LDPE/Bismuth oxide nanocomposite: Preparation, characterization and application in X-ray shielding. Polymers 13(18): 3081.

Bawazeer, O., Albakri, H., Makkawi, K., Aga, Z.B., Alomari, A., Adil, S.F., Algethami, M., Assiri, N., Alsubhi, A., Qutub, M., Alotaibi, E., Khan, S.A., Althagafy, K., Al-Qahtani, S., Althomali, M. & Ajlouni, A.W. 2025. Evaluation of X-ray shielding performance of Bi/PMMA andBi/PMMA–TiO2/PMMA nanocomposites. Radiation Physics and Chemistry 231: 112596.

Charkiewicz, A.E. & Backstrand, J.R. 2020. Lead toxicity and pollution in Poland. International Journal of Environmental Research and Public Health 17(12): 4385.

Hazim, A., Abduljalil, H.M. & Hashim, A. 2020. Analysis of structural and electronic properties of novel (PMMA/Al2O3, PMMA/Al2O3-Ag, PMMA/ZrO2, PMMA/ZrO2-Ag, PMMA-Ag) Nanocomposites for low cost electronics and optics applications. Transactions on Electrical and Electronic Materials 21(1): 48-67.

Hedaya, A., Elsafi, M., Al-Saleh, W.M. & Saleh, I.H. 2024. Effect of Bi2O3 particle size on the radiation-shielding performance of free-lead epoxide materials against ionizing radiation. Polymers 16(15): 2125.

Johnson, T.E. & Cember, H. 2017. Introduction to Health Physics. Fifth Edition. McGraw-Hill Education.

Klein, L.W., Miller, D.L., Balter, S., Laskey, W., Haines, D., Norbash, A., Mauro, M.A. & Goldstein, J.A. 2009. Occupational health hazards in the interventional laboratory: Time for a safer environment. Radiology 250(2): 538-544.

Marshall, S.K., Boonpeng, K., Buapud, N., Chimhashat, S., Chuaymuang, J., Kwandee, P. & Songphum, N. 2025. Bismuth oxide nanoparticle-enhanced poly(methyl methacrylate) composites for I-131 radiation shielding: A combined simulation and experimental investigation. Polymers 17(5): 590.

Mazrani, W., McHugh, K. & Marsden, P.J. 2007. The radiation burden of radiological investigations. Archives of Disease in Childhood 92(12): 1127-1131.

Muthamma, M.V., Prabhu, S., Bubbly, S.G. & Gudennavar, S.B. 2021. Micro and nano Bi2O3 filled epoxy composites: Thermal, mechanical and γ-ray attenuation properties. Applied Radiation and Isotopes 174: 109780.

Ortaç, B., Baskan, T., Mutlu, S., Yilmaz, S.S. & Yilmaz, A.H. 2025. Gamma radiation shielding efficiency of cross-linked polystyrene-b-polyethyleneglycol block copolymer nanocomposites doped arsenic (III) oxide and boron nitride nanoparticles. Polymers 17(24): 3330.

Sayyed, M.I., Hanan Al-Ghamdi, Almuqrin, A.H., Yasmin, S. & Elsafi, M. 2022. A study on the gamma radiation protection effectiveness of nano/micro-MgO-reinforced novel silicon rubber for medical applications. Polymers 14(14): 2867.

Zulkifli, Z.A., Razak, K.A. & Rahman, W.N.W.A. 2017. Effect of hydrothermal reaction time on size of bismuth oxide nanoparticles synthesized via hydrothermal method. AIP Conference Proceedings 1901: 020011.

Zulkifli, Z.A., Razak, K.A., Rahman, W.N.W.A. & Abidin, S.Z. 2018. Synthesis and characterisation of bismuth oxide nanoparticles using hydrothermal method: The effect of reactant concentrations and application in radiotherapy. Journal of Physics: Conference Series 1082: 012103.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 